Main specification:

 500 MA HF X-RAY

1. It is microcomputer procedure control and high frequency single x-ray tube and diagnostic table x-ray equipment.

2. To be equipped with 150kV, 50kW X-ray tube. High-frequency technology Constant DC output, not only improve the image quality and greatly reduce the radiation hazards to patients.

3. Main circuit using intelligent modules, not only to improve the radiation output reproducibility and linearity, while ensuring long-term safety of the machine is running reliably and has fault self-diagnosis function.

4. The machine has 2000 kinds of exposure conditions, also, exposure conditions can be chooses according to user’s demand, which providing a great convenience for clinical use.

5. The vertical and horizontal movement of radiography tabletop is flexible and can bear for a variety of specifications of cassettes; it is easy to use and beautiful in design.

6. It is applicable to the hospital for general photography, photographic filter line browser, apparatus procedures radiography (APR), etc.

 

Department

Technical parameter

High frequency generator

Power

Voltage

380V±10%

frequency

50Hz±1Hz

capacity

≥50KVA

Internal resistance

≤0.15Ω

AEC control time

Min. 4ms

mAs

1800 mAs

Radiography

current

32-800mA  adjustable dividedly

voltage

45-150KV  adjustable continuously

Time of exposure

0.01-6.3s ,23 grades

Mode of choice

Save a total of 128 kinds of exposure conditions, can also be freely chosen by the operator

X-ray assembly

Output power

≥22/54kW

Anode heat storage capacity

≥230kHU

focus

Double focus 0.6/1.2mm

Speed of anode rotating

2800r/min

Imported Collimator

radiation field

Manual adjustable field of view, adjustable continuously

Light field

luminosity≥100LX1min limit-time device

CDG/CDGI

Multi function radiography table

Moving table

Lengthways

±600mm

Electromagnetism locking

 

Across

±120mm

 

Mobile beam filtration grid

Grid density

28L/cm

 

Grid ratio

81

 

Focusing distance

100cm

 

Scope of moving

≥600mm

 

Radiography item

5″×7″8″×10″10″×12″11″×14″

12″×15″14″×14″14″×17″

 

Distance from surface to film

75mm

 

Height of bed

700mm

 

Moving pillar

±180°per 90°orientation, moving lengthways ≥1500mm

 

Bulb tube

Rotate the cross arm±180ascend $ descend 1100mm

 

               

Option: LSJ pillar radiography frame

LSJ pillar radiography frame

The scope of ascend and descend

1450mm

The minimum distance from focal spot

380mm

Radiography item

8"×10 10×12

11×1412×15

14×14 14×17

Fixed beam filtration role

Grid density

40L/cm

Grid radio

10:1

Focal distance

180cm

 